Vertical Recon Plate 01 Stationed hotspot map Plate 01 Stationed hotspot map PDF · KMZ
Sample deliverable · not for reliance
Candidates located by station and offset along the reach.
- KMZ
Vertical Recon
Every engagement ends in a documented deliverable set. What follows are specimen plates — demonstration data, built to the standards and formats you receive.
Sample deliverable · demonstration data throughout
How to read a plate
Set 01
For irrigation district boards
The scan locates and ranks probable seepage. It does not measure water volume.
Download the full set — PDF, 8 pagesSample only. This PDF shows the format of a report. It describes no real property, client or finding, and it is not for project, claim or purchasing decisions. Downloading it acknowledges the terms of use and the privacy policy.
Sample deliverable · not for reliance
Candidates located by station and offset along the reach.
Sample deliverable · not for reliance
| ID | Station | Offset | ΔT °C | Severity | Status |
|---|---|---|---|---|---|
| ANOM-03 | 26+40 | 6 m L | 4.2 | High | Verify on ground |
| ANOM-01 | 14+20 | 4 m L | 3.1 | Moderate | Verify on ground |
| ANOM-02 | 19+60 | 2 m R | 2.4 | Low | Verify on ground |
| ANOM-04 | 22+70 | 3 m R | 0.9 | Low | Verify on ground |
Ranked by thermal difference, every row flagged for ground verification.
Ranked by thermal difference, every row flagged for ground verification.
Sample deliverable · not for reliance
Thermal · 8–14 µm
Visible · same pass
Registered to one another · 4 candidates carried across
The same reach in both bands, from the same pass over the same ground.
Sample deliverable · not for reliance
Section at station
Surface model
Bank and channel geometry, for cross-sections and for the next flight.
Sample deliverable · not for reliance
Conditions on the day, settings logged, and the limits of the result.
Sample deliverable · not for reliance
| Product | Format | Contents |
|---|---|---|
| Thermal orthomosaic | GeoTIFF | Georeferenced thermal raster of the reach |
| Visible orthomosaic | GeoTIFF | Georeferenced visible-light raster, same extent |
| Surface model | DSM · LAZ | Photogrammetric — from overlapping camera capture |
| Anomaly register | CSV · GeoPackage | Numbered anomalies by canal name, station and offset, plus coordinates; ΔT, severity, flag |
| Map package | KMZ | Anomaly points and reach extent for the district GIS |
| Report | Cover, method, conditions, findings, limitations |
What lands in the folder, and in what.
Next step · Scope your project
If the format is right for your board, your engineer or your lender, a short call sizes the job and sets the capture window.
We reply within one business day.
Set 02
For building owners and insurers
An ASTM C1153 survey flown after sunset, on the window where saturated insulation still holds the day's heat. Four plates: where the suspect areas are, what has to be cored before any of them is called wet, the same roof in daylight, and the conditions the result depends on.
The method, in fullSample deliverable · not for reliance
Suspect areas outlined on the plan grid, numbered and totaled.
Sample deliverable · not for reliance
| ID | Grid | Est. area | ΔT °C | Verify by | Reading | Status |
|---|---|---|---|---|---|---|
| WET-01 | C4–D5 | 42 m² | 2.8 | Core | [Core pending] | Unverified |
| WET-02 | F2–F3 | 18 m² | 1.9 | Core | [Core pending] | Unverified |
| WET-03 | B6 | 27 m² | 3.4 | Core | [Core pending] | Unverified |
| WET-04 | G5 | 9 m² | 1.4 | Core | [Core pending] | Unverified At drain — rule out ponding first |
| Total | 96 m² | Estimated suspect area · none confirmed | ||||
Every area is reported unverified until a core returns a reading. Infrared indicates; the core confirms.
One row per area on the map, every one flagged for a core.
Sample deliverable · not for reliance
The daylight pass, registered to the same plan and grid.
Sample deliverable · not for reliance
ASTM C1153 infrared roof moisture survey
Roof Area B-2 · method, conditions and limitations
Conditions required
Limitations
Indication, not confirmation
Infrared finds patterns consistent with retained moisture. Standing water, recent repairs, differing membrane materials and rooftop equipment produce the same signature, so every anomaly is verified by a core — at least one per roof section, one in dry insulation and one in each anomaly type — and unverified anomalies are reported as unverified.
The window governs the scan
The survey is flown at night, from about an hour after sunset, after a day of sun, with no appreciable rain in the previous 24 hours and wind under about 15 mph. A daylight visual pass follows within two days. If the conditions do not hold, the flight moves.
Not survey work
The plan is a scaled schematic for locating findings. It is not a boundary, a benchmark, or an authoritative survey, and areas are estimates supplied for relative use.
Written consent
Every flight is flown under written authorization from the building owner.
The standard we follow, the conditions we work to, and what infrared cannot settle.
Set 03
For facility managers and auditors
An inspection read with the equipment running and loaded, because an unloaded circuit reads ambient. Four plates: the thermogram paired with the component it sits on, every difference measured against the identical part on the phase beside it, the equipment list that makes next year's report comparable with this one, and the conditions the readings depend on.
The method, in fullSample deliverable · not for reliance
The same component twice — the difference, and the part it sits on.
Sample deliverable · not for reliance
| ID | Asset | Component | Load | Access | ΔT ref °C | ΔT air °C | Class | Action |
|---|---|---|---|---|---|---|---|---|
| EL-01 | MCC-01 D2 | A-phase lug, bucket 3B | 62% of rating | Cover off | 21.4 | 37.6 | 4 | Repair now |
| EL-02 | SWGR-01 C2 | B-phase cable termination, bay 2 | 58% of rating | Cover off | 8.6 | 23.4 | 3 | Monitor until it can be corrected |
| EL-03 | PNL-A F2 | Branch breaker 14 | 44% of rating | IR window | 5.2 | 15.7 | 2 | Schedule the repair |
| EL-04 | XFMR-01 A3 | C-phase secondary bushing | 51% of rating | Cover off | 2.3 | 20.7 | 2 | Schedule the repair |
| EL-05 | DISC-01 A1 | Polished enclosure face | 51% of rating | Cover off | [Re-read pending] | [Re-read pending] | — | Re-read against an emissivity reference Unpainted surface — apparent temperature may be reflected |
| Total | 5 | 0 × Class 1 · 2 × Class 2 · 1 × Class 3 · 1 × Class 4 · 1 unclassified | ||||||
Two differences per anomaly, because NFPA 70B lists both and prefers neither. ΔT ref is against the identical component on the adjacent phase, at the same load, on the same day. ΔT air is against the ambient air, which is what shows a lineup running warm as a set, where every phase agrees with every other. Class is graded on both and reports the more severe, on the ANSI/NETA MTS bands: Class 1 investigate, Class 2 repair as time permits, Class 3 monitor until it can be corrected, Class 4 repair immediately. Class 3 has no like-for-like band, so a finding reaches it on the ambient comparison alone. A finding names the component running hot and by how much; what is wrong inside it is determined by opening, testing or servicing the equipment.
Every anomaly measured twice — against a like part at a like load, and against the ambient air — then graded on the NETA bands.
Sample deliverable · not for reliance
| Tag | Equipment | Grid | Location | Findings |
|---|---|---|---|---|
| DISC-01 | Outdoor disconnect | A1 | Outdoor pad | EL-05 |
| XFMR-01 | Pad transformer | A3 | Outdoor pad | EL-04 |
| SWGR-01 | Switchgear, two bays | C2 | Electrical room | EL-02 |
| MCC-01 | Motor control center | D2 | Electrical room | EL-01 |
| MCC-02 | Motor control center | E2 | Electrical room | None |
| PNL-A | Panelboard, wall mounted | F2 | Electrical room | EL-03 |
| BUS-01 | Busway, overhead with drop | C3–E3 | Electrical room | None |
What was scanned and where it sits, indoors and out, tagged for the next inspection.
Sample deliverable · not for reliance
NFPA 70B electrical thermography — method and program record
Electrical Room A-2 · conditions, classification and limitations
Conditions of the inspection
Severity classification · like-for-like · vs ambient
Every anomaly carries two measured differences beside its class: against the identical component on the adjacent phase at the same load, and against the ambient air. NFPA 70B lists both bases and prefers neither, so both are on every row rather than one with the other in reserve. Classes are graded on the ANSI/NETA MTS bands. Class is graded on both comparisons and reports the more severe. Whether each panel was scanned open or through an IR window is recorded beside it.
ANSI/NETA MTS, 2011 edition. Reproduced as Table 1 of Zarco-Periñán, Zarco-Soto, Zarco-Soto & Martínez-Ramos, Applied Sciences 12(20), 10381 (2022), open access CC BY 4.0. Class is graded on both comparisons and reports the more severe; Class 3 has no like-for-like band, so a finding reaches it on the ambient comparison alone.
Limitations
What a finding is
Thermography tells you which part is running hot, by how much, and compared to what. Finding out why — a loose lug, a failing winding, a worn bearing — takes opening, testing or servicing the equipment. Your electricians and millwrights do that.
An unloaded circuit reads room temperature
A bad connection only makes heat when current runs through it. The inspection is scheduled around production, not around a shutdown, and the load is recorded beside every anomaly instead of assumed.
Surface, not interior
What is measured is the outside of the equipment. A polished or unpainted face reports reflected temperature rather than its own, so a reading taken on one is re-read against an emissivity reference before it is classified.
What the report is not
It documents measured conditions and grades them against a published convention. It does not certify equipment as fit for service, and it does not stand in for an engineer of record.
Covers
Covers on energized equipment come off under your site electrical safety program, by your qualified electrician or a qualified contractor we coordinate. We scan, measure, classify and document. We do not open energized equipment.
Written consent
We hold written authorization from the facility owner or operator before every visit and every flight.
Retained as the program record — the inspection, its conditions, its findings and the equipment list — in the form an auditor and an underwriter both accept.
The standard, the conditions, the classes, and what infrared cannot settle.
Sample deliverable · not for reliance
The same visit and the same table, on a motor: a bearing read against the other bearing on its own shaft.
Deliverable specifications
Sample deliverable · not for reliance
For GCs, owners and lenders
Not a survey. Photogrammetric products document conditions for planning and comparison; boundary determinations and certified elevations are performed by a licensed Idaho professional land surveyor.
Sample deliverable · not for reliance
For engineers and planners
Not a survey. Photogrammetric products document conditions for planning and comparison; boundary determinations and certified elevations are performed by a licensed Idaho professional land surveyor.
Sample deliverable · not for reliance
For solar owners and O&M teams
Sample deliverable · not for reliance
For growers and agronomists
Applies to every plate above
Every plate above carries a “Sample deliverable · not for reliance” stamp inside its frame. Imagery we capture, or process from public data, carries one of two labels, written in full:
Captured by Vertical ReconOnly for imagery our own aircraft flew.
Processed by Vertical Recon from public USGS 3DEP / USDA NAIP data, [year]For specimens built from public data, with the year verified at the source.
The reason to publish the rules alongside the specimens is simple: the label on a document is the only part of it a buyer cannot verify without flying the site themselves.
Next step · The document
We reply within one business day.